Flow Cytometry Test
Flow cytometry is a laboratory test that passes cells in a fluid stream through lasers to measure their size, complexity and the fluorescent antibody markers (CD antigens) on each cell. It is used to diagnose and classify leukemias and lymphomas, count CD4 T cells in HIV, detect PNH and measure minimal residual disease.
- Specimen
- EDTA or heparin peripheral blood, bone marrow aspirate, body fluids and fresh tissue in RPMI; viability falls with time, so ship at room temperature and test quickly.
- CLIA complexity
- High complexity
- CLIA specialty
- Hematology and immunology (flow cytometry)
- Common CPT codes
- 88184, 88185, 88187-88189
How it works
- Stain: Cells from blood, bone marrow, fluid or tissue are labeled with fluorochrome-conjugated antibodies.
- Acquire: Thousands to millions of cells are measured individually by the cytometer's lasers and detectors.
- Gate and analyze: Populations are separated by gating; abnormal populations are characterized by their marker pattern.
- Interpret: A pathologist or qualified director writes the interpretation.
Common flow cytometry tests
- Leukemia/lymphoma immunophenotyping panels
- CD4/CD8 T-cell counts
- PNH (FLAER-based) testing
- Minimal/measurable residual disease (MRD)
- B-cell and lymphocyte subset counts for immunodeficiency and therapy monitoring
Specimen collection
- EDTA or heparin peripheral blood, bone marrow aspirate, body fluids and fresh tissue in RPMI; viability falls with time, so ship at room temperature and test quickly.
Accuracy, results and interpretation
- Interpretation requires correlation with morphology, cytogenetics and molecular findings.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Clinical flow cytometers | BD FACSLyric/FACSCanto, Beckman DxFLEX/Navios, Cytek Northern Lights CLC | High (panels largely LDTs) |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 88184 | Flow cytometry, cell surface/cytoplasmic/nuclear marker, technical component, first marker |
| 88185 | Each additional marker |
| 88187-88189 | Flow cytometry interpretation, 2-8, 9-15, and 16 or more markers |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Document daily instrument setup and fluorescence standardization, compensation and validation of each antibody combination and gating template.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the hematology and immunology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256. |
| Proficiency testing | Where no approved proficiency testing exists for a test, verify its accuracy at least twice a year, for example by split-sample comparison or an available external survey (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Hematology and immunology lab consulting.
How Sound Lab Consultants helps labs offering Flow cytometry test
Bringing Flow cytometry test in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
How long does a flow cytometry test take?
Many labs report preliminary leukemia/lymphoma results within 24 hours; final interpretation may wait for morphology and other studies.
Related lab test guides