Fire Safety and Emergency Action Plan Course for Laboratories
Lab fire prevention, RACE and PASS, extinguisher classes, flammable storage, evacuation and the OSHA Emergency Action Plan.
Free30 min5 lessons10-question quiz
Lessons
Lesson 1: Fire risks in the lab
Labs combine ignition sources (hot plates, Bunsen burners, electrical equipment) with flammable liquids such as alcohols, xylene and acetone. Prevention is the best control: keep only the quantity of flammables you need, store them in approved flammable storage cabinets, keep them away from heat, and never store flammables in a standard (non-explosion-safe) refrigerator.
Lesson 2: The Emergency Action Plan
OSHA's Emergency Action Plan standard (29 CFR 1910.38) requires employers to have a plan covering how fires and emergencies are reported, evacuation procedures and routes, accounting for employees after evacuation, and who to contact. Employers with more than 10 employees must have a written plan; smaller employers may communicate it orally. Know your exits, alarm pull stations, extinguishers and meeting point.
Lesson 3: RACE: what to do in a fire
- Rescue anyone in immediate danger if it is safe to do so.
- Alarm: pull the fire alarm and call 911 (or your facility's emergency number).
- Contain the fire by closing doors.
- Extinguish a small fire if you are trained and it is safe, or Evacuate.
Lesson 4: Extinguishers and PASS
- Class A: ordinary combustibles (paper, cloth). Class B: flammable liquids and gases. Class C: energized electrical equipment. Class D: combustible metals. Class K: cooking oils. Most labs have ABC extinguishers.
- Use PASS: Pull the pin, Aim at the base of the fire, Squeeze the handle, Sweep side to side.
- Only fight a fire that is small and contained, with your back to an exit. If in doubt, get out.
- OSHA requires employers who expect employees to use extinguishers to train them at hire and at least annually (29 CFR 1910.157).
Lesson 5: Keeping exits and equipment clear
- Never block exits, corridors, fire doors, extinguishers or alarm stations.
- Keep storage below sprinkler heads (commonly at least 18 inches of clearance).
- Never prop open fire doors.
- Report damaged extinguishers or missing inspection tags.
Quiz and certificate
Answer all 10 questions. Score 80% or higher to get your free certificate from Sound Lab Consultants - Technical Consultants.
Under CLIA, everyone who performs non-waived testing must have documented training before reporting patient results, and documented competency assessment at 6 months and 12 months in the first year and annually after that. The six required methods are direct observation of routine testing, monitoring of recording and reporting of results, review of worksheets, QC and maintenance records, direct observation of maintenance and function checks, testing of previously analyzed or external samples, and assessment of problem-solving skills (42 CFR 493.1451 and 493.1413). Waived testing follows the manufacturer's instructions and your lab's own training and competency policy. This course documents training. It does not replace the competency assessment your laboratory director or technical consultant must perform at your site.
More free courses
PATHFAST Immunoanalyzer Operator Course · Sysmex XP-300 Hematology Analyzer Operator Course · Abaxis Piccolo Xpress Chemistry Analyzer Operator Course · Phlebotomy, Specimen Processing and Transport Course · All courses
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultationor call (602) 874-1311