Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Free lab SOP template · Waived testing and point-of-care testing

Urine Dipstick (Reagent Strip) Testing SOP Template

Free, fillable urine dipstick (reagent strip) testing standard operating procedure for CLIA waived complexity labs. Download it as a PDF form or a Word document. No email required.

Short answer: A urine dipstick SOP covers specimen handling, timing of reading, visual or analyzer reading, QC and reporting. This free template downloads as a fillable PDF and an editable Word file.

Last reviewed November 26, 2026. Governing requirement: 42 CFR 493.15(e) (follow manufacturer's instructions) and 493.1773-1775.

WaivedModerate complexity (n/a)High complexity (n/a)

These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use.

First page of the free Urine Dipstick (Reagent Strip) Testing SOP template, a fillable PDF and Word form for CLIA waived complexity laboratories
Page 1 of the Urine Dipstick (Reagent Strip) Testing SOP template, with fillable header fields, applicability boxes and the director approval block.

What this Urine Dipstick (Reagent Strip) Testing SOP must contain

Purpose: To perform chemical urinalysis by reagent strip.

Scope: [Testing sites] performing the Urine Dipstick under the lab's CLIA certificate.

The template includes these sections:

  • Header block: laboratory name, CLIA number, document number, version, effective date, next review, author, approval by the laboratory director with signature and date
  • Purpose and scope
  • Responsibility by role
  • Definitions
  • Materials, equipment and records
  • Step-by-step procedure (6 steps)
  • Quality control
  • Interpretation, reporting and documentation
  • Limitations and cautions
  • References to the governing regulation and guidance
  • Fillable form: QC and patient testing log (7 columns)
  • Lab-specific notes
  • Revision history and annual review log (fillable)

Why labs need it

This procedure supports 42 CFR 493.15(e) (follow manufacturer's instructions) and 493.1773-1775. Under 42 CFR 493.1251, a nonwaived laboratory must have written procedures that staff follow, and the laboratory director must approve, sign and date each procedure and every change before use. Waived labs must follow the manufacturer's instructions exactly, and written procedures help show they do. Surveyors and accreditation inspectors usually ask to see the procedure, the related records and evidence that staff were trained on it.

Procedure outline

The highlighted items are fill-in fields in the PDF and Word versions.

  1. Test fresh urine within 2 hours or refrigerate and bring to room temperature.
  2. Mix the specimen; dip the strip briefly, drain the edge.
  3. Read each pad at the time stated by the manufacturer under good lighting, or use the analyzer.
  4. Record results using the chart terms.
  5. Run positive and negative controls [QC frequency per manufacturer] and with each new lot or bottle.
  6. Keep bottle capped; do not touch pads.

Quality control and documentation

  • Follow the laboratory's QC policy and the manufacturer's instructions; record QC before reporting patient results.
  • Stop patient testing and take corrective action when QC or acceptance criteria are not met.
  • Report results with units or grades as on the chart.

Limitations

  • Ascorbic acid, highly colored urine and old specimens can interfere.
  • This is a generic template. Adapt it to your instruments, test systems, manufacturer instructions, state law and accreditation standards before use.

Key definitions

  • Reagent strip: Plastic strip with reagent pads for analytes such as glucose, protein, blood, leukocyte esterase and nitrite.

Fields you fill in

Besides the header block, revision history and annual review log, this template has 4 lab-specific fields:

  • Testing sites
  • Brand and lot
  • Analyzer ID
  • QC frequency per manufacturer

How to adopt this template

  1. Download the PDF or Word version above.
  2. Fill in the header block and every highlighted field. Where a field says "per manufacturer", copy the value from your current package insert or operator manual.
  3. Delete steps that do not apply and add any steps your test system or state requires.
  4. Have the technical consultant or technical supervisor review it, then have the laboratory director sign and date it before use.
  5. Train staff, document their review, and add the SOP to your document control master list.

Need procedures written for your lab?

Sound Lab Consultants writes and reviews complete procedure manuals that match your instruments, test menu and certificate type. Book a free consultation to talk through what your lab needs.

Book a free consultation

Frequently asked questions

Is this Urine Dipstick (Reagent Strip) Testing SOP template free?

Yes. The Urine Dipstick (Reagent Strip) Testing SOP template is a free download as a fillable PDF and an editable Word (.docx) file. There is no email gate or sign-up.

What regulation does a urine dipstick (reagent strip) testing procedure address?

This template is built around 42 CFR 493.15(e) (follow manufacturer's instructions) and 493.1773-1775. Read the current text at the official source linked on this page, and check your state and accreditation organization for added requirements.

Can our lab use this SOP as-is?

No. Use it as a starting point. Fill in the highlighted fields, adapt the steps to your instruments and the manufacturer's instructions, and have the laboratory director approve, sign and date it before use (42 CFR 493.1251(d)).

Which labs is this template for?

It is written for waived complexity laboratories, as marked in the template's 'Applies to' boxes. Uncheck any that do not apply to your lab.

How do I fill in the PDF?

Open the PDF in a PDF reader that supports forms, click the shaded fields and type. Save a copy. In the Word version, click each highlighted field (a content control) and type over it.

Does a Certificate of Waiver lab need written procedures?

CLIA requires waived labs to follow the manufacturer's instructions exactly. Written procedures and logs are strongly recommended by CDC and help show that instructions are followed and staff are trained.

Official sources

These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use. Sound Lab Consultants is not affiliated with or endorsed by CMS, CDC, FDA, OSHA, HHS, CAP, COLA, The Joint Commission, CLSI, any state agency, or any instrument or reagent manufacturer. CLSI and other standards are referenced by name only. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.