Specimen Acceptance and Rejection Criteria SOP Template

Free, fillable specimen acceptance and rejection criteria standard operating procedure for CLIA waived, moderate and high complexity labs. Download it as a PDF form or a Word document. No email required.

Short answer: A specimen rejection SOP lists the criteria for acceptable specimens and what to do with unacceptable ones, including how to report and document the rejection. This free template downloads as a fillable PDF and an editable Word file.

Last reviewed November 26, 2026. Governing requirement: 42 CFR 493.1242(a)(8) and 493.1291(c)(7).

WaivedModerate complexityHigh complexity

These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use.

First page of the free Specimen Acceptance and Rejection Criteria SOP template, a fillable PDF and Word form for CLIA waived, moderate and high complexity laboratories
Page 1 of the Specimen Acceptance and Rejection Criteria SOP template, with fillable header fields, applicability boxes and the director approval block.

What this Specimen Acceptance and Rejection Criteria SOP must contain

Purpose: To define criteria for specimen acceptability and the handling of specimens that do not meet them.

Scope: All specimens received for testing.

The template includes these sections:

  • Header block: laboratory name, CLIA number, document number, version, effective date, next review, author, approval by the laboratory director with signature and date
  • Purpose and scope
  • Responsibility by role
  • Definitions
  • Materials, equipment and records
  • Step-by-step procedure (5 steps)
  • Quality control
  • Interpretation, reporting and documentation
  • Limitations and cautions
  • References to the governing regulation and guidance
  • Fillable form: Specimen rejection log (7 columns)
  • Lab-specific notes
  • Revision history and annual review log (fillable)

Why labs need it

This procedure supports 42 CFR 493.1242(a)(8) and 493.1291(c)(7). Under 42 CFR 493.1251, a nonwaived laboratory must have written procedures that staff follow, and the laboratory director must approve, sign and date each procedure and every change before use. Waived labs must follow the manufacturer's instructions exactly, and written procedures help show they do. Surveyors and accreditation inspectors usually ask to see the procedure, the related records and evidence that staff were trained on it.

Procedure outline

The highlighted items are fill-in fields in the PDF and Word versions.

  1. Reject specimens that are unlabeled or mislabeled, have mismatched identifiers, wrong tube or preservative, insufficient volume, are clotted (for whole blood tests), hemolyzed/icteric/lipemic beyond test limits [Index limits], leaking, expired stability or wrong temperature.
  2. Notify the ordering location promptly and request recollection; document who was notified and when.
  3. For irretrievable specimens, the director or designee may approve testing; the person who collected must correct identification and the report must note the problem.
  4. Record the rejection in the LIS and rejection log.
  5. Include information on condition and disposition of unacceptable specimens on the report (493.1291(c)(7)).

Quality control and documentation

  • Review rejection rates monthly by location and reason.
  • Record the activity, date, result and initials on the form or log, and have the supervisor review records [Review frequency].
  • Keep records per the record retention SOP (at least 2 years under 42 CFR 493.1105 unless a longer period applies).

Limitations

  • This is a generic template. Adapt it to your instruments, test systems, manufacturer instructions, state law and accreditation standards before use.

Key definitions

  • Irretrievable specimen: A specimen that cannot be recollected (for example CSF, tissue, pre-treatment cultures).

Fields you fill in

Besides the header block, revision history and annual review log, this template has 2 lab-specific fields:

  • Index limits
  • Review frequency

How to adopt this template

  1. Download the PDF or Word version above.
  2. Fill in the header block and every highlighted field. Where a field says "per manufacturer", copy the value from your current package insert or operator manual.
  3. Delete steps that do not apply and add any steps your test system or state requires.
  4. Have the technical consultant or technical supervisor review it, then have the laboratory director sign and date it before use.
  5. Train staff, document their review, and add the SOP to your document control master list.

Need procedures written for your lab?

Sound Lab Consultants writes and reviews complete procedure manuals that match your instruments, test menu and certificate type. Book a free consultation to talk through what your lab needs.

Book a free consultation

Frequently asked questions

Is this Specimen Acceptance and Rejection Criteria SOP template free?

Yes. The Specimen Acceptance and Rejection Criteria SOP template is a free download as a fillable PDF and an editable Word (.docx) file. There is no email gate or sign-up.

What regulation does a specimen acceptance and rejection criteria procedure address?

This template is built around 42 CFR 493.1242(a)(8) and 493.1291(c)(7). Read the current text at the official source linked on this page, and check your state and accreditation organization for added requirements.

Can our lab use this SOP as-is?

No. Use it as a starting point. Fill in the highlighted fields, adapt the steps to your instruments and the manufacturer's instructions, and have the laboratory director approve, sign and date it before use (42 CFR 493.1251(d)).

Which labs is this template for?

It is written for waived, moderate and high complexity laboratories, as marked in the template's 'Applies to' boxes. Uncheck any that do not apply to your lab.

How do I fill in the PDF?

Open the PDF in a PDF reader that supports forms, click the shaded fields and type. Save a copy. In the Word version, click each highlighted field (a content control) and type over it.

Official sources

These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use. Sound Lab Consultants is not affiliated with or endorsed by CMS, CDC, FDA, OSHA, HHS, CAP, COLA, The Joint Commission, CLSI, any state agency, or any instrument or reagent manufacturer. CLSI and other standards are referenced by name only. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.