Short answer: A specimen shipping SOP covers triple packaging, UN3373 marking and training needed to ship Category B and exempt patient specimens to referral labs. This free template downloads as a fillable PDF and an editable Word file.
Last reviewed November 26, 2026. Governing requirement: 49 CFR 173.199 (Category B) and 42 CFR 493.1242(c).
These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use.
What this Specimen Packaging and Shipping (UN3373) SOP must contain
Purpose: To package and ship patient specimens safely and legally.
Scope: Specimens shipped by courier or common carrier to referral laboratories.
The template includes these sections:
- Header block: laboratory name, CLIA number, document number, version, effective date, next review, author, approval by the laboratory director with signature and date
- Purpose and scope
- Responsibility by role
- Definitions
- Materials, equipment and records
- Step-by-step procedure (7 steps)
- Quality control
- Interpretation, reporting and documentation
- Limitations and cautions
- References to the governing regulation and guidance
- Lab-specific notes
- Revision history and annual review log (fillable)
Why labs need it
This procedure supports 49 CFR 173.199 (Category B) and 42 CFR 493.1242(c). Under 42 CFR 493.1251, a nonwaived laboratory must have written procedures that staff follow, and the laboratory director must approve, sign and date each procedure and every change before use. Waived labs must follow the manufacturer's instructions exactly, and written procedures help show they do. Surveyors and accreditation inspectors usually ask to see the procedure, the related records and evidence that staff were trained on it.
Procedure outline
The highlighted items are fill-in fields in the PDF and Word versions.
- Classify the specimen as Category B or exempt [Classification guidance].
- Place primary container in secondary packaging with enough absorbent for the entire contents.
- Place itemized list of contents between secondary and outer packaging.
- Mark outer package with UN3373 and 'Biological Substance, Category B' and shipper/consignee information.
- If using dry ice, mark UN1845 and net weight and allow venting.
- Ensure the person packaging has current training [Training records location].
- Record shipment and tracking number.
Quality control and documentation
- Follow the laboratory's QC policy and the manufacturer's instructions; record QC before reporting patient results.
- Stop patient testing and take corrective action when QC or acceptance criteria are not met.
- Record the activity, date, result and initials on the form or log, and have the supervisor review records [Review frequency].
- Keep records per the record retention SOP (at least 2 years under 42 CFR 493.1105 unless a longer period applies).
Limitations
- Category A substances require specialized training and packaging; do not ship them under this SOP.
- This is a generic template. Adapt it to your instruments, test systems, manufacturer instructions, state law and accreditation standards before use.
Key definitions
- Category B: Infectious substance not meeting Category A criteria; shipped as UN3373 Biological Substance, Category B.
- Exempt human specimen: A specimen with minimal likelihood of pathogens, shipped as 'Exempt human specimen'.
Fields you fill in
Besides the header block, revision history and annual review log, this template has 3 lab-specific fields:
- Classification guidance
- Training records location
- Review frequency
How to adopt this template
- Download the PDF or Word version above.
- Fill in the header block and every highlighted field. Where a field says "per manufacturer", copy the value from your current package insert or operator manual.
- Delete steps that do not apply and add any steps your test system or state requires.
- Have the technical consultant or technical supervisor review it, then have the laboratory director sign and date it before use.
- Train staff, document their review, and add the SOP to your document control master list.
Need procedures written for your lab?
Sound Lab Consultants writes and reviews complete procedure manuals that match your instruments, test menu and certificate type. Book a free consultation to talk through what your lab needs.
Book a free consultationFrequently asked questions
Is this Specimen Packaging and Shipping (UN3373) SOP template free?
Yes. The Specimen Packaging and Shipping (UN3373) SOP template is a free download as a fillable PDF and an editable Word (.docx) file. There is no email gate or sign-up.
What regulation does a specimen packaging and shipping (un3373) procedure address?
This template is built around 49 CFR 173.199 (Category B) and 42 CFR 493.1242(c). Read the current text at the official source linked on this page, and check your state and accreditation organization for added requirements.
Can our lab use this SOP as-is?
No. Use it as a starting point. Fill in the highlighted fields, adapt the steps to your instruments and the manufacturer's instructions, and have the laboratory director approve, sign and date it before use (42 CFR 493.1251(d)).
Which labs is this template for?
It is written for waived, moderate and high complexity laboratories, as marked in the template's 'Applies to' boxes. Uncheck any that do not apply to your lab.
How do I fill in the PDF?
Open the PDF in a PDF reader that supports forms, click the shaded fields and type. Save a copy. In the Word version, click each highlighted field (a content control) and type over it.
Official sources
- eCFR, 49 CFR 173.199 (Category B) and 42 CFR 493.1242(c)
- PHMSA, 49 CFR 173.199 Category B infectious substances (UN3373)
- CDC, Infectious diseases laboratory test directory: specimen collection and submission
- eCFR, 42 CFR 493.1242
Related SOP templates
These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use. Sound Lab Consultants is not affiliated with or endorsed by CMS, CDC, FDA, OSHA, HHS, CAP, COLA, The Joint Commission, CLSI, any state agency, or any instrument or reagent manufacturer. CLSI and other standards are referenced by name only. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.