Short answer: A personnel qualifications policy explains how the lab verifies that each person meets CLIA Subpart M education, training and experience requirements for their role, and what goes in each personnel file. This free template downloads as a fillable PDF and an editable Word file.
Last reviewed November 26, 2026. Governing requirement: 42 CFR 493 Subpart M (493.1403-493.1495).
These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use.
What this Personnel Qualifications and Records Policy SOP must contain
Purpose: To ensure every person performing or supervising nonwaived testing meets CLIA Subpart M and state qualification requirements before starting work, and that evidence is on file.
Scope: All laboratory personnel: laboratory director, technical consultant, technical supervisor, clinical consultant, general supervisor, cytotechnologists and testing personnel.
The template includes these sections:
- Header block: laboratory name, CLIA number, document number, version, effective date, next review, author, approval by the laboratory director with signature and date
- Purpose and scope
- Responsibility by role
- Definitions
- Materials, equipment and records
- Step-by-step procedure (9 steps)
- Quality control
- Interpretation, reporting and documentation
- Limitations and cautions
- References to the governing regulation and guidance
- Fillable form: Personnel file checklist (7 columns)
- Lab-specific notes
- Revision history and annual review log (fillable)
Why labs need it
This procedure supports 42 CFR 493 Subpart M (493.1403-493.1495). Under 42 CFR 493.1251, a nonwaived laboratory must have written procedures that staff follow, and the laboratory director must approve, sign and date each procedure and every change before use. Waived labs must follow the manufacturer's instructions exactly, and written procedures help show they do. Surveyors and accreditation inspectors usually ask to see the procedure, the related records and evidence that staff were trained on it.
Procedure outline
The highlighted items are fill-in fields in the PDF and Word versions.
- Identify the CLIA role(s) the employee will hold and the complexity of testing.
- Collect evidence of education (diploma, transcript or primary source verification), certification and state license as applicable [State license requirements].
- For foreign education, obtain an equivalency evaluation from an acceptable credential evaluation service.
- Confirm the qualification pathway in the applicable section: moderate complexity (493.1405, 1411, 1417, 1423); high complexity (493.1443, 1449, 1455, 1461, 1483, 1489).
- Document required experience and training for the pathway used.
- Have the laboratory director (or designee) sign that qualifications were verified before work begins.
- List each employee and role on the personnel roster and, for CMS surveys, on Form CMS-209 when requested.
- Re-verify licenses at renewal [Renewal tracking method].
- Keep files for active staff and for [Retention period after separation] after separation.
Quality control and documentation
- Audit [Number] personnel files per year against the checklist.
- A missing credential means the person may not test until it is obtained.
Limitations
- State licensure (for example CA, NY, FL and others) can be stricter than CLIA.
- This is a generic template. Adapt it to your instruments, test systems, manufacturer instructions, state law and accreditation standards before use.
Key definitions
- Primary source verification: Confirming a credential directly with the issuing school, board or agency.
- Personnel file: The record of qualifications, training, competency and job description for one employee.
Fields you fill in
Besides the header block, revision history and annual review log, this template has 4 lab-specific fields:
- State license requirements
- Renewal tracking method
- Retention period after separation
- Number
How to adopt this template
- Download the PDF or Word version above.
- Fill in the header block and every highlighted field. Where a field says "per manufacturer", copy the value from your current package insert or operator manual.
- Delete steps that do not apply and add any steps your test system or state requires.
- Have the technical consultant or technical supervisor review it, then have the laboratory director sign and date it before use.
- Train staff, document their review, and add the SOP to your document control master list.
Need procedures written for your lab?
Sound Lab Consultants writes and reviews complete procedure manuals that match your instruments, test menu and certificate type. Book a free consultation to talk through what your lab needs.
Book a free consultationFrequently asked questions
Is this Personnel Qualifications and Records Policy SOP template free?
Yes. The Personnel Qualifications and Records Policy SOP template is a free download as a fillable PDF and an editable Word (.docx) file. There is no email gate or sign-up.
What regulation does a personnel qualifications and records policy procedure address?
This template is built around 42 CFR 493 Subpart M (493.1403-493.1495). Read the current text at the official source linked on this page, and check your state and accreditation organization for added requirements.
Can our lab use this SOP as-is?
No. Use it as a starting point. Fill in the highlighted fields, adapt the steps to your instruments and the manufacturer's instructions, and have the laboratory director approve, sign and date it before use (42 CFR 493.1251(d)).
Which labs is this template for?
It is written for moderate and high complexity laboratories, as marked in the template's 'Applies to' boxes. Uncheck any that do not apply to your lab.
How do I fill in the PDF?
Open the PDF in a PDF reader that supports forms, click the shaded fields and type. Save a copy. In the Word version, click each highlighted field (a content control) and type over it.
Official sources
- eCFR, 42 CFR 493 Subpart M (493.1403-493.1495)
- eCFR, 42 CFR Part 493 Subpart M: Personnel for nonwaived testing
- CMS, State Operations Manual Appendix C: Survey procedures and interpretive guidelines for laboratories
- CMS, Clinical Laboratory Improvement Amendments (CLIA)
Related SOP templates
These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use. Sound Lab Consultants is not affiliated with or endorsed by CMS, CDC, FDA, OSHA, HHS, CAP, COLA, The Joint Commission, CLSI, any state agency, or any instrument or reagent manufacturer. CLSI and other standards are referenced by name only. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.