Short answer: An exposure control plan is the written OSHA plan that identifies jobs with blood exposure and sets engineering controls, work practices, PPE, hepatitis B vaccination, post-exposure follow-up, training and records. This free template downloads as a fillable PDF and an editable Word file.
Last reviewed November 26, 2026. Governing requirement: OSHA 29 CFR 1910.1030.
These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use.
What this Bloodborne Pathogens Exposure Control Plan SOP must contain
Purpose: To eliminate or minimize occupational exposure to blood and other potentially infectious materials (OPIM).
Scope: All employees with reasonably anticipated occupational exposure at [Facility name].
The template includes these sections:
- Header block: laboratory name, CLIA number, document number, version, effective date, next review, author, approval by the laboratory director with signature and date
- Purpose and scope
- Responsibility by role
- Definitions
- Materials, equipment and records
- Step-by-step procedure (11 steps)
- Quality control
- Interpretation, reporting and documentation
- Limitations and cautions
- References to the governing regulation and guidance
- Fillable form: Sharps injury log (7 columns)
- Lab-specific notes
- Revision history and annual review log (fillable)
Why labs need it
This procedure supports OSHA 29 CFR 1910.1030. Under 42 CFR 493.1251, a nonwaived laboratory must have written procedures that staff follow, and the laboratory director must approve, sign and date each procedure and every change before use. Waived labs must follow the manufacturer's instructions exactly, and written procedures help show they do. Surveyors and accreditation inspectors usually ask to see the procedure, the related records and evidence that staff were trained on it.
Procedure outline
The highlighted items are fill-in fields in the PDF and Word versions.
- Exposure determination: list job classifications with exposure [Job classifications] and tasks [Tasks].
- Use universal precautions.
- Engineering controls: safety-engineered sharps, sharps containers, splash shields, biosafety cabinets; evaluate safer devices annually with input from front-line staff.
- Work practices: no recapping, no eating or drinking in work areas, hand washing after glove removal.
- Provide PPE at no cost and require its use.
- Housekeeping: decontaminate surfaces after contact and at end of shift [Disinfectant].
- Offer hepatitis B vaccination within 10 working days of assignment; keep declinations.
- Post-exposure: wash site, report immediately, document route, test source if consent obtained, refer to [Occupational health provider] for evaluation and prophylaxis.
- Label regulated waste and refrigerators with the biohazard symbol.
- Train at assignment and annually; keep records 3 years.
- Maintain a sharps injury log; review and update this plan at least annually.
Quality control and documentation
- Inspect safety equipment and supplies on the schedule in this plan and record results.
- Review incidents and near misses at least quarterly.
- Medical records kept for duration of employment plus 30 years.
Limitations
- This is a generic template. Adapt it to your instruments, test systems, manufacturer instructions, state law and accreditation standards before use.
Key definitions
- OPIM: Other potentially infectious materials, as defined in 1910.1030(b).
- Universal precautions: Treating all human blood and OPIM as infectious.
Fields you fill in
Besides the header block, revision history and annual review log, this template has 5 lab-specific fields:
- Facility name
- Job classifications
- Tasks
- Disinfectant
- Occupational health provider
How to adopt this template
- Download the PDF or Word version above.
- Fill in the header block and every highlighted field. Where a field says "per manufacturer", copy the value from your current package insert or operator manual.
- Delete steps that do not apply and add any steps your test system or state requires.
- Have the technical consultant or technical supervisor review it, then have the laboratory director sign and date it before use.
- Train staff, document their review, and add the SOP to your document control master list.
Need procedures written for your lab?
Sound Lab Consultants writes and reviews complete procedure manuals that match your instruments, test menu and certificate type. Book a free consultation to talk through what your lab needs.
Book a free consultationFrequently asked questions
Is this Bloodborne Pathogens Exposure Control Plan SOP template free?
Yes. The Bloodborne Pathogens Exposure Control Plan SOP template is a free download as a fillable PDF and an editable Word (.docx) file. There is no email gate or sign-up.
What regulation does a bloodborne pathogens exposure control plan procedure address?
This template is built around OSHA 29 CFR 1910.1030. Read the current text at the official source linked on this page, and check your state and accreditation organization for added requirements.
Can our lab use this SOP as-is?
No. Use it as a starting point. Fill in the highlighted fields, adapt the steps to your instruments and the manufacturer's instructions, and have the laboratory director approve, sign and date it before use (42 CFR 493.1251(d)).
Which labs is this template for?
It is written for waived, moderate and high complexity laboratories, as marked in the template's 'Applies to' boxes. Uncheck any that do not apply to your lab.
How do I fill in the PDF?
Open the PDF in a PDF reader that supports forms, click the shaded fields and type. Save a copy. In the Word version, click each highlighted field (a content control) and type over it.
Official sources
- Governing requirement: OSHA 29 CFR 1910.1030
- OSHA, 29 CFR 1910.1030 Bloodborne pathogens
- OSHA, 29 CFR 1904 Recordkeeping (Form 300 log)
- CDC, Guidelines for safe work practices in human and animal medical diagnostic laboratories (MMWR 2012)
Related SOP templates
These templates are free, general starting points, not legal or regulatory advice. Every template must be reviewed and approved, signed and dated by your laboratory director, and adapted to your lab's instruments, test systems and the manufacturer's instructions, your state rules and your accreditation organization's standards before use. Sound Lab Consultants is not affiliated with or endorsed by CMS, CDC, FDA, OSHA, HHS, CAP, COLA, The Joint Commission, CLSI, any state agency, or any instrument or reagent manufacturer. CLSI and other standards are referenced by name only. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.